Services

Calibration
Laboratory
Polonia Aero provides also a high-quality calibration service. Calibration Department is equipped with a range of high accuracy multifunction calibrators and multimeters. We can calibrate voltage and current reference sources (e.g. a variety range of DC/AC Gauges, National Instrument PXI boards etc.).

Voltage DC
Calibration object
Measurement range
Measurement uncertainty for CMC
Place of performance
Measurement method
Digital voltage meters
40 µV ÷ 200 mV
200 mV ÷ 1 V
(1 ÷ 10) V
(1 ÷ 21) V
200 mV ÷ 1 V
(1 ÷ 10) V
(1 ÷ 21) V
17 µV
0,05 mV
0,0004 V
0,0007 V
0,05 mV
0,0004 V
0,0007 V
S-stationary
+
P - at the customer site
+
P - at the customer site
DK-M-02
(according to EURAMET cg-15, version 3.0, 02/2015)
(according to EURAMET cg-15, version 3.0, 02/2015)
Calibrators reference sources
1 mV ÷ 1 V
(1 ÷ 10) V
(10 ÷ 20) V
(1 ÷ 10) V
(10 ÷ 20) V
0,09 mV
0,0007 V
0,0015 V
0,0007 V
0,0015 V
S-stationary
+
P - at the customer site
+
P - at the customer site
DK-M-02
(according to EURAMET cg-15, version 3.0, 02/2015)
(according to EURAMET cg-15, version 3.0, 02/2015)
Current DC
Calibration object
Measurement range
Measurement uncertainty for CMC
Place of performance
Measurement method
Digital current meters
10 µA ÷ 5 mA
(5 ÷ 10) mA
(10 ÷ 20) mA
(5 ÷ 10) mA
(10 ÷ 20) mA
2 µA
0,004 mA
0,007 mA
0,004 mA
0,007 mA
S-stationary
+
P - at the customer site
+
P - at the customer site
DK-M-02
(according to EURAMET cg-15, version 3.0, 02/2015)
(according to EURAMET cg-15, version 3.0, 02/2015)
Calibrators reference sources
10 µA ÷ 6 mA
(6 ÷ 10) mA
(10 ÷ 24) mA
(6 ÷ 10) mA
(10 ÷ 24) mA
6 µA
0,008 mA
0,017 mA
0,008 mA
0,017 mA
S-stationary
+
P - at the customer site
+
P - at the customer site
DK-M-02
(according to EURAMET cg-15, version 3.0, 02/2015)
(according to EURAMET cg-15, version 3.0, 02/2015)
Voltage AC
Calibration object
Measurement range
Measurement uncertainty for CMC
Place of performance
Measurement method
Digital current meters
20 Hz ÷ 100 kHz
(1 ÷ 10) mV
(10 ÷ 500) mV
(500 ÷ 1000) mV
(1000 ÷ 2000) mV
(2 ÷ 5) V
(5 ÷ 10) V
(10 ÷ 20) V
(1 ÷ 10) mV
(10 ÷ 500) mV
(500 ÷ 1000) mV
(1000 ÷ 2000) mV
(2 ÷ 5) V
(5 ÷ 10) V
(10 ÷ 20) V
0,08 mV
1,3 mV
2 mV
4 mV
0,01 V
0,02 V
0,04 V
1,3 mV
2 mV
4 mV
0,01 V
0,02 V
0,04 V
S-stationary
+
P - at the customer site
+
P - at the customer site
DK-M-02
(according to EURAMET cg-15, version 3.0, 02/2015)
(according to EURAMET cg-15, version 3.0, 02/2015)
Differential Pressure
Calibration object
Measurement range
Measurement uncertainty for CMC
Place of performance
Measurement method
Electronic pressure gauges
(-55 ÷ 689,5) kPa
0,094 kPa
S-stationary
+
P - at the customer site
+
P - at the customer site
DKD-R 6-1
edition 03/2014
edition 03/2014